  • High-Performance 3phase VFD for Pumps and Fans
  • High-Performance 3phase VFD for Pumps and Fans
  • High-Performance 3phase VFD for Pumps and Fans
  • High-Performance 3phase VFD for Pumps and Fans
  • High-Performance 3phase VFD for Pumps and Fans
  • High-Performance 3phase VFD for Pumps and Fans
Find Similar Products

Basic Info.

Model NO.
M300
Principle of Work
V/F Control Transducer
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type, Textile Special, Constant Torque Universal Type
Brand
Rbca
Speed Ratio
1:100
Max.Output Frequency
1000Hz
Control Method
V/F Control
Communciation
485 Communication
Environment Temp.
-10-50 Degree C
Braking Unit
Build-in
Output Frequency
50Hz/60Hz
Kw Range
0.75kw-2.2kw
Transport Package
Export Seaworthy Package
Trademark
RBCA
Origin
China
HS Code
85044090
Production Capacity
20000/Month

Product Description

 
input Rated voltage,frequency Three phase (4T Series) 380V; 50 / 60Hz three phase (2t Series) 220V: 50 / 60Hz
Allowable variation range of voltage Three phase (4T Series) 320v ~ 460V three phase (2t Series) 190V ~ 250V
output Voltage 4T series; 0 ~ 380V 2T series; 0 ~ 220V
frequency 0~600HZ
Overload capacity 110% long term 150% 1 minute 180% 5 seconds
control mode V / F control, simple vector control
Control characteristics Frequency setting resolution Analog input 0.1% of maximum output frequency
Digital setting 0.1HZ
Frequency accuracy Analog input Within 0.2% of maximum output frequency
Digital input Set the output frequency within 0.01%
V/F control V / F curve (voltage frequency characteristic) The reference frequency can be set arbitrarily from 5 Hz to 600 Hz, the multi point V / F curve can be set arbitrarily, and a variety of fixed curves such as constant torque, low reduced torque 1, low reduced torque 2 and square torque can also be selected
Torque lifting Manual setting: 0.0 ~ 30.0% of rated output
Automatic lifting: according to the output current and motor parameters, automatically determine the lifting torque
Automatic current limiting and voltage limiting Whether in the process of acceleration, deceleration or stable operation, the stator current and voltage of the motor are automatically detected, and the unique algorithm is used to suppress the current and voltage within the allowable range, so as to minimize the possibility of system fault tripping
Control characteristics Sensorless vector control Voltage frequency characteristic The output voltage frequency ratio is automatically adjusted according to the motor parameters and unique algorithm
Torque characteristics Starting torque:
100% rated torque at 5.0hz (VF control)
150% rated torque at 1.5Hz (simple vector control)
Current and voltage suppression Full range current closed-loop control, completely avoid current impact, with perfect over-current and over-voltage suppression function
Under voltage suppression in operation Especially for the users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the longest possible operation time according to the unique algorithm and residual energy allocation strategy even if the voltage is lower than the allowable range
Typical functions Multi speed operation 7-segment programmable multi-stage speed control, multiple operation modes are optional.
PID control Built in PID controller (preset frequency). Standard configuration of RS485 communication function, a variety of communication protocols optional, with linkage synchronization control function
RS485 communication
Frequency setting Analog input DC voltage 0 ~ 10V, DC current 0 ~ 20mA (upper and lower limit optional)
Digital input Operation panel setting, RS485 interface setting, up / DW terminal control, and various combination settings with analog input
output signal Digital output 1 channel OC output and 1 channel fault relay output (TA, TB, TC), up to 14 meaning options
Analog output One analog signal output, the output range is 0 ~ 20mA or 0 ~ 10V, which can realize the output of physical quantity such as setting frequency and output frequency
Automatic stable operation According to the needs, dynamic voltage stabilization, static voltage stabilization and non voltage stabilization can be selected to obtain the most stable operation effect
Acceleration and deceleration time setting 0.1s ~ 999.9min continuous setting
braking Energy consumption braking The starting voltage, return differential voltage and energy consumption braking rate can be adjusted continuously
DC brake Starting frequency of DC braking at shutdown: 0.00 ~ [f0.05] upper limit frequency
Braking time: 0.0 ~ 30.0S; braking current: 0.0% ~ 50.0% of motor rated voltage
Low noise operation Carrier frequency 1.0khz ~ 16.0khz can be adjusted continuously to minimize motor noise
Counter One internal counter, convenient for system integration
Operation function Setting of upper and lower frequency, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increasing, decreasing control, fault self recovery operation, etc
display Operation panel display running state Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback, analog input and output, etc
Alarm content Output frequency, set frequency, output current, output voltage, DC voltage, module temperature and other operating parameters recorded during the last fault trip
Protection function Over current, over voltage, under voltage, module failure, electronic thermal relay, overheating, short circuit, internal memory failure, etc
Environmental Science Ambient temperature - 10 ºC~ + 40 ºC (if the ambient temperature is between 40 ºC and 50 ºC, please reduce the rating for use)
Ambient humidity 5% - 95% RH, no water condensation
surrounding environment Indoor (no direct sunlight, corrosion, flammable gas, oil mist, dust, etc.)
altitude Derating for more than 1000m, with 10% derating for every 1000m increase
structure Protection level IP20
Cooling mode Air cooled with fan control
Installation mode Wall mounted, cabinet

 
Overall dimensions The size of hole The thickness of the
W H W1 H1 D
104.4 76.3 98.2 67.5 22

b.Overall dimension
0.75KW-2.2KW/220V  1.5KW-4.0KW/380V
 
Voltage grade specifications power(kW) Overall dimensions(mm) Installation dimensions(mm) Packing size(mm)
The net weight(kg)
W1 H1 D W2 H2 φ long wide height
220VSingle phase M300-2SR75G/1.5P 0.75 95.5 158.5 132.5 83.5 145 4.5 195 132 172 1.23
M300-2S01R5G/2.2P 1.5
M300-2S02R2G/4P 2.2

Superior performance, can achieve 4 control modes

The highest operating frequency HKUST 3000HZ

Automatic slip compensation-more accurate speed

Excellent torque output: 150% rated torque at 3.0HZ (VF control)

0.5HZ180% rated torque (current vector control)

High overload capacity-150% rated torque can last for 60 seconds

Ultra-low noise, the carrier frequency can be adjusted between 1-16K (set by model)

Timely and reliable control and protection, high system stability

Product Features:

1. Can be equipped with LCD panel, dual-line digital tube panel, single-line digital tube panel

2. Pulse train I/O function

3. Running time and power consumption record

4. Speed and torque control

5. Separate VF control

6. Swing frequency control

7. Fixed length control

8. PID control air energy

9. Communication function

10. The panel has a parameter copy function