• K10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input Inverter
  • K10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input Inverter
  • K10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input Inverter
  • K10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input Inverter
  • K10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input Inverter
  • K10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input Inverter

K10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input Inverter

Application: High-performance Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Current
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Selection guide
Overview

Basic Info.

Model NO.
K10-2SR75G
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type
Brand
Rbca
Power Range
0.75-2.2kw
Environment Temp.
-10 -- 50
Max.Output Frequency
1000Hz
Braking Unit
Build-in
Transport Package
Carton
Trademark
RBCA
Origin
China
HS Code
85044090
Production Capacity
5000/Month

Product Description

Product Description
 

 

Input Rated voltage, frequency Three-phase (4T series ) 380V;50/60HZ  Single phase (2 S series) 220V: 50/60HZ 
Allowable voltage variation range Three-phase (4T series ) 320V ~ 460V    Single phase (2 S series) 190V~250V
Output Voltage 4T series; 0~380V 2 S series; 0~220V
Frequency V/ F control, simple vector control : 0.0 ~ 999.9HZ
Advanced vector control , torque control : 0.5 ~ 300.0 HZ
Overload capacity 110% long term 150% 1 minute 180% 5 seconds
Control method V/F control, simple vector control, advanced vector control, torque control
Control characteristics Frequency setting resolution Analog input 0.1% of maximum output frequency
Digital settings 0.1HZ
Frequency accuracy Analog input Within 0.2% of the maximum output frequency
digital input Within 0.01% of the set output frequency
V/F control V/F curve (voltage frequency characteristics) Three methods: the first is the linear torque characteristic curve, the second is the square torque characteristic curve, and the third is the user-set V/F curve.
Torque boost Manual setting: 0.0~30.0% of rated output
Automatic lifting: automatically determine the lifting torque according to the output current and combined with the motor parameters
Automatic current limiting and pressure limiting Whether during acceleration, deceleration or stable operation, the motor stator current and voltage are automatically detected and suppressed within the allowable range based on a unique algorithm to minimize the possibility of system fault tripping.
Inductive vector control Voltage frequency characteristics Automatically adjust the output voltage-to-frequency ratio based on motor parameters and unique algorithm
Torque characteristics Starting torque:
100% rated torque at 5.0Hz (VF control)
150% rated torque at 1.0Hz (vector control)
Current and voltage suppression Full current closed-loop control, completely avoiding current impact, with complete overcurrent and overvoltage suppression functions
Undervoltage suppression during operation Especially for users with low grid voltage and frequent fluctuations in grid voltage, even if the voltage is lower than the allowed voltage range, the system can maintain the longest possible operating time based on a unique algorithm and residual energy allocation strategy.
Typical functions Multi-speed operation 7-segment programmable multi-segment speed control, multiple operating modes available.
PID control
RS485 communication
Built-in PID controller (frequency can be preset). Standard configuration RS485 communication function, multiple communication protocols optional, with linkage synchronous control function
Frequency setting Analog input DC voltage 0~10V, DC current 0~20mA (upper and lower limits optional)
Digital input Operation panel setting, RS485 interface setting, UP/DOWN terminal control, and various combination settings with analog input
output signal Relay output 1 relay output (TA, TC), up to 17 meaning options
Analog output 1 analog signal output, the output range can be flexibly set between 0~20mA or 0~10V, which can realize the output of physical quantities such as set frequency and output frequency.
Automatic voltage stabilization operation You can choose dynamic voltage stabilization, static voltage stabilization, or unstabilized voltage according to your needs to obtain the most stable operating effect.
Acceleration and deceleration time setting 0.1S~999.9min continuously configurable
Brake Energy consumption braking Energy consumption braking starting voltage, hysteresis voltage and energy consumption braking rate are continuously adjustable
DC braking Stop DC braking starting frequency: 0.00~[F0.05] upper limit frequency
Braking time: 0.0~30.0s; Braking current: 0.0%~50.0% of motor rated voltage
Low noise operation The carrier frequency is continuously adjustable from 2.0KHZ to 20.0KHZ to minimize motor noise.
counter An internal counter to facilitate system integration
run function Upper and lower limit frequency settings, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc.
 
Display Operation panel display Operating status Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc.
Alarm content Records of output frequency, set frequency, output current, output voltage, DC voltage, module temperature and other operating parameters during the latest fault
Protective function Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, internal memory failure, etc.
Environment Ambient temperature -10ºC~+40ºC (environment temperature is between 40ºC~50ºC, please derate for use)
Ambient humidity 5%~95%RH, no water droplets condensation
Surroundings Indoor (no direct sunlight, no corrosion, flammable gas, oil mist, dust, etc.)
Altitude Derating for use above 1000 meters, derate by 10% for every 1000 meters.
Structure Protection level IP20
Cooling method Air-cooled, with fan control
Installation method Wall-mounted
Selection guide

 

K10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input InverterK10 New VFD 0.75kw 1.5kw 2.2kw Single Phase 220V Input Inverter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
16800000 RMB
Plant Area
1001~2000 square meters