Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Voltage level | Rated power (KW) | Rated output current (A) | Adapted motor (KW) |
220V single phase | 0.75 | 4.5 | 0.75 |
1.5 | 7.0 | 1.5 | |
2.2 | 10 | 2.2 | |
380V three-phase | 0.75 | 2.3 | 0.75 |
1.5 | 3.7 | 1.5 | |
2.2 | 5 | 2.2 | |
4.0 | 9 | 4 | |
5.5 | 13 | 5.5 | |
7.5 | 17 | 7.5 | |
11 | 24 | 11 | |
15 | 33 | 15 | |
18.5 | 39 | 18.5 | |
22 | 45 | 22 | |
30 | 62 | 30 | |
37 | 75 | 37 | |
45 | 90 | 45 | |
380V three-phase | 55 | 110 | 55 |
75 | 150 | 75 | |
90 | 176 | 90 | |
110 | 210 | 110 | |
132 | 260 | 132 | |
160 | 310 | 160 | |
185 | 360 | 185 | |
220 | 420 | 220 | |
250 | 475 | 250 | |
280 | 535 | 280 | |
315 | 595 | 315 | |
350 | 660 | 350 | |
400 | 730 | 400 | |
500 | 930 | 500 | |
630 | 1150 | 630 |
enter | rated voltage, frequency |
Three-phase (4T# series ) 380V; 50/60Hz Single phase ( 2 S# series ) 220 V; 50/60Hz |
|||
voltage allowed Range of change |
Three-phase (4T# series ) 320V ~ 460V Single phase (2S# series ) 16 0V ~ 260 V |
||||
output | Voltage | 4T# series ; 0 ~ 460V 2S# series ; 0 ~ 260V |
|||
frequency | Low frequency mode: 0~300Hz High frequency mode: 0~3000Hz | ||||
overload capacity | G-type machine: 110% long-term 150% 1 minute 180% 5 seconds P-type machine: 105% long-term 120% 1 minute 150% 1 second |
||||
control method | V/F control, advanced V/F control, V/F separation control, current vector control | ||||
control characteristics | frequency setting resolution |
Analog input | 0.1% of the maximum output frequency | ||
digital setting | 0.01Hz | ||||
Frequency Accuracy | analog input | Within 0.2% of the maximum output frequency | |||
digital input | Within 0.01% of the set output frequency | ||||
V/F control | V/F curve (voltage frequency characteristics) | The reference frequency can be set arbitrarily from 5 to 600Hz, and the multi-point V/F curve can be set arbitrarily, and various fixed curves such as constant torque, low reduced torque 1, low reduced torque 2, and square torque can also be selected | |||
torque boost | Manual setting: 0.0 to 30.0% of rated output Automatic boost: automatically determine the boost torque according to the output current and combined with the motor parameters |
||||
Automatic current limiting and pressure limiting | No matter in the process of acceleration, deceleration or stable operation, it will automatically detect the motor stator current and voltage, and suppress it within the allowable range according to the unique algorithm, minimizing the possibility of system fault tripping | ||||
control characteristics | Sensorless vector control | Voltage Frequency Characteristics | Automatically adjust output voltage-frequency ratio according to motor parameters and unique algorithm | ||
Torque characteristics | Starting torque: 150% rated torque at 3.0Hz (VF control) 180% rated torque at 0.5Hz (current vector control without PG, magnetic flux vector control) 180% rated torque at 0.05Hz (with PG current vector control) Steady-state accuracy of running speed: ≤±0.2% of rated synchronous speed Speed fluctuation: ≤±0.5% rated synchronous speed Torque response: ≤50ms, vector control with PG, vector control without PG, magnetic flux vector control ≤20ms |
||||
Self-determination of motor parameters | Without any restrictions, the automatic detection of parameters can be completed under the static and dynamic conditions of the motor to obtain the best control effect | ||||
current and voltage suppression | Full current closed-loop control, completely avoid current impact, with perfect overcurrent and overvoltage suppression function | ||||
running UVR |
Especially for users with low grid voltage and frequent grid voltage fluctuations, even if the voltage is lower than the allowable range, the system can maintain the longest possible running time according to the unique algorithm and residual energy allocation strategy | ||||
typical function | Multi-speed and Wobble operation |
16-segment programmable multi-segment speed control, multiple operating modes are optional. Wobble frequency operation: preset frequency, adjustable center frequency, state memory and recovery after power failure | |||
PID control RS485 communication |
Built-in PID controller (frequency can be preset). Standard RS485 communication function, a variety of communication protocols are optional, with linkage synchronization control function | ||||
frequency setting | analog input | DC voltage 0~10V, DC current 0~20mA (upper and lower limit optional) | |||
digital input | Operation panel setting, RS485 interface setting, UP/DW terminal control, and various combination setting with analog input | ||||
output signal | digital output | 2-way OC output and one-way fault relay output (TA, TB, TC), up to 16 kinds of meaning options | |||
analog output | 2 channels of analog signal output, the output range can be flexibly set between 0~20mA or 0~10V, which can realize the output of physical quantities such as set frequency and output frequency | ||||
Automatic voltage regulation operation | According to the needs, three modes of dynamic voltage regulation, static voltage regulation and unregulated voltage can be selected to obtain the most stable operation effect | ||||
Acceleration, deceleration time setting |
0.1s ~ 3600min continuous can be set, S-type, linear mode optional | ||||
brake | energy consumption brake |
Dynamic braking initial voltage, hysteresis voltage and dynamic braking rate are continuously adjustable | |||
DC brake |
Start frequency of DC braking at stop: 0.00~F0.16upper limit frequency Braking time: 0.0~100.0s; Braking current: 0.0%~150.0% of rated current |
||||
magnetic flux brake |
0~100 0: invalid | ||||
low noise operation | The carrier frequency is continuously adjustable from 1.0KHz to 16.0KHz to minimize motor noise | ||||
speed tracking speed restart function |
It can realize the smooth restart of the motor in operation and the function of restart after instantaneous power failure | ||||
counter | One internal counter, convenient for system integration | ||||
running function | Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc. |
show | Operation panel display | run state |
Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback value, analog input and output, etc. |
alarm content |
Records of the latest six faults, records of six operating parameters such as output frequency, set frequency, output current, output voltage, DC voltage, and module temperature when the latest fault tripped | ||
Protective function | Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal tuning of motor parameters, internal memory failure, etc. | ||
environment | ambient temperature | -10ºC~+50ºC | |
ambient humidity | 5%~95%RH, no condensation | ||
surroundings | Indoor (no direct sunlight, no corrosion, no flammable gas, no oil mist, dust, etc.) | ||
altitude | Use with derating above 1000 meters, derate 10% for every 1000 meters | ||
structure | degree of protection | IP20 | |
cooling method | Air-cooled, with fan control | ||
installation method | wall-mounted, cabinet |