• 250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine
  • 250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine
  • 250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine
  • 250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine
  • 250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine
  • 250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine

250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine

Application: Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
H900
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type, Textile Special, Constant Torque Universal Type
Brand
Rbca
Speed Ratio
1:100
Max.Output Frequency
1000Hz
Control Method
V/F Control
Communciation
485 Communication
Environment Temp.
-10-50 Degree C
Braking Unit
Build-in
Input Frequency
50Hz/60Hz
Kw Range
0.75kw-630kw
Transport Package
Export Seaworthy Package
Trademark
RBCA
Origin
China
HS Code
85044090
Production Capacity
5000/Month

Product Description

Input Rated voltage, frequency Three-phase AC 380V;50/60Hz
Single phase AC 220 V;50/60Hz
voltage allowed
Range of
change
Three-phase AC 3 80 V ~ 4 8 0V
Single-phase AC 220 V ~ 2 6 0 V
Output Voltage 0 ~ 480V _ _
0 ~ 260V
Frequency Vector control: 0~500Hz V/F control: 0~5000Hz
Overload capacity G type machine: 150% rated current for 60s; 180% rated current for 3s. P type machine: 120% rated current for 60s; 150% rated current for 3s.
Control method V/F control, speed sensorless vector control (SVC)
Control
 characteristics
Frequency setting resolution Analog input Maximum frequency×0.025%
Digital settings 0.01Hz
V/F control V/F curve Three methods: linear type; multi-point type;
N-th power V/F curve
(1.2 power, 1.4 power, 1.6 power, 1.8 power, 2 power)
 
    V/F separation 2 ways: full separation, semi-separation
Torque boost Manual setting: 0.0~30.0% of rated output Automatic lifting: automatically determine the lifting torque according to the output current and combined with the motor parameters
Automatic current limiting and pressure limiting Whether during acceleration, deceleration or stable operation, it can automatically detect the motor stator current and voltage, and suppress it within the allowable range based on a unique algorithm to minimize the possibility of system fault tripping.
Control characteristics Inductive vector control Voltage frequency
characteristics
Automatically adjust the output voltage-to-frequency ratio based on motor parameters and unique algorithm
Torque characteristics Starting torque:
150% rated torque at 3.0Hz (V/F control) 150% rated torque at 0.5Hz (vector control
without speed sensor)
Operating speed steady-state accuracy: ≤±0.2% rated synchronous speed
Speed fluctuation: ≤±0.5% rated synchronous speed
Torque response: ≤20ms (vector control without speed sensor)
Self-determination of motor parameters Without any restrictions, automatic parameter detection can be completed under both static and dynamic conditions of the motor to obtain the best control effect.
Current and voltage Full current closed-loop control, completely
 
    suppression avoiding current impact, with complete overcurrent and overvoltage suppression functions
Under voltage suppression
during
operation
Especially for users with low grid voltage and frequent fluctuations in grid voltage, even if the voltage is lower than the allowed voltage range, the system can maintain the longest possible operating time based on a unique algorithm and residual energy allocation strategy.
Typical functions Multi-speed and swing frequency operation 16-segment programmable multi-segment speed control, multiple operating modes available. Swing frequency operation: preset frequency and center frequency are adjustable, state memory and recovery after power outage
PID control RS485 communication Built-in PID controller (frequency can be preset), standard configuration RS485 communication function
Frequency setting Analog input DCvoltage0~10V,DCcurrent0~20mA(upper and lower limits optional)
digital input Operation panel setting, RS485 interface setting, UP/DOWN terminal control, and various combination settings with analog input
output signal digital output 2 Y terminal open collector outputs and 2 programmable relay outputs(TA,TB,TC),up to 58 meaning options
Analog output 2 analog signal outputs, the output range can beflexiblysetbetween0~20mAor0~10V,which can realize the output of physical quantities such as set frequency and output frequency.
Automatic voltage stabilization operation You can choose dynamic voltage stabilization, static voltage stabilization, or unstabilized voltage according to your needs to obtain the most stable operating effect.
Acceleration and deceleration time setting 0.0s~6500.0s can be set continuously, S-shaped and linear modes are
optional
brake Energy consumption
brake
Energy consumption braking starting voltage,hysteresis voltage and energy consumption braking rate are continuously adjustable
DC brake Stop DC braking starting frequency: 0.00~[F00.10] maximum frequency
Braking time: 0.0~100.0s; Braking current: 0%~100% rated current
  Low noise operation The carrier frequency is continuously adjustable from 0.5KHz to 16.0KHz to minimize motor noise.
RPM tracking speed restart function It can realize smooth restart and instantaneous stop restart function of the running motor.
counter An internal counter to facilitate system integration
run function Upper and lower limit frequency settings,frequency jump operation,reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc.
Display Operation panel display run state Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc.
alarm content There are 8 operating parameter records including output frequency, set frequency,output current,output voltage,DC voltage,module temperature, power-on time, and running time when three faults trip.
Protective function Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal motor parameter tuning, internal memory failure, etc.
environment ambient temperature -10ºC~+40ºC (environment temperature is between 40ºC~50ºC, please derate for use)
ambient humidity 5%~95%RH, no water droplets condensation
surroundings Indoor (no direct sunlight, no corrosion, flammable gas, oil mist, dust, etc.)
altitude Derating for use above 1000 meters, derate by 10% for every 1000 meters.
structure Protection level IP20
cooling method Air-cooled, with fan control
Installation method Wall-mounted, cabinet type


1. Magnetic flux vector control, without self-learning, provides higher performance than ordinary V/F;

2. Aluminum alloy heat dissipation, easy disassembly of the heat dissipation fan, stable heat dissipation guarantee to adapt to complex working conditions such as dust and cotton wool;

3. Small size, saving customer installation space;

4. Standard LED keyboard with potentiometer and externally available;

5. The product design strictly follows the IEC national standard and meets the CE certification test requirements;

6. Automatic slip compensation-more accurate speed;

7. Automatic torque compensation-up to 150% when starting at 3HZ;

8. High overload capacity-150% rated torque can last for 60 seconds;

9. Ultra-low noise, the carrier frequency can be adjusted between 1-15K (depending on the model);

10. The control and protection are timely and reliable, and the system stability is high;

11. Set a variety of commonly used functions to meet application requirements:

(1) Standard Modbus communication

(2) Process PID control

(3) With 16 speed control

(4) 0~1000HZ high frequency output

(5) Multi-point V/F curve setting is possible

(6) Speed tracking function, automatically search for motor speed, and restart without stopping

(7) Single week and cycle counting function



250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine


(8) With multi-function input and output ports, and the switch value can be set to delay time

(9) It has protection functions such as over current, over voltage, under voltage, over temperature, overload, etc., and can save fault information

(10) There are multiple options for DC braking, magnetic flux braking, and resistance energy consumption braking

(11) Over-current stall, over-voltage stall, response to sudden load changes

(12) V/F curve can be adjusted according to load characteristics

(13) Pulse train I/O function

(14) Multi-speed control function

(15) Stop deceleration/restart after instantaneous power failure

(16) PID control function

(17) Communication function

(18) Main and auxiliary frequency input function

(19) One internal counter

(20) Torque detection function

250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine


250kw 220kw 380VAC 3-Phase Variable Frequency Drive for Crusher Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
16800000 RMB
Plant Area
1001~2000 square meters