High-Performance VFD for Plastic Machinery with 2000Hz Output

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Still deciding? Get samples of US$ 100/Piece
Request Sample
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (30)
  • High-Performance VFD for Plastic Machinery with 2000Hz Output
  • High-Performance VFD for Plastic Machinery with 2000Hz Output
  • High-Performance VFD for Plastic Machinery with 2000Hz Output
  • High-Performance VFD for Plastic Machinery with 2000Hz Output
  • High-Performance VFD for Plastic Machinery with 2000Hz Output
  • High-Performance VFD for Plastic Machinery with 2000Hz Output
Find Similar Products

Basic Info.

Model NO.
A900
Principle of Work
V/F Control Transducer
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type, Textile Special, Constant Torque Universal Type
Brand
Rbca
Speed Ratio
1:100
Max.Output Frequency
2000Hz
Control Method
V/F Control
Communciation
485 Communication
Environment Temp.
-10-50 Degree C
Braking Unit
Build-in
Output Frequency
50Hz/60Hz
Kw Range
0.75kw-630kw
Transport Package
Export Seaworthy Package
Trademark
RBCA
Origin
China
HS Code
8504409999
Production Capacity
3000/Month

Product Description

We extend our heartfelt gratitude to you for choosing the A600 High-Performance Vector Control Inverter, a hallmark of innovation and excellence, masterfully crafted by Jiangsu Robin Kang Automation Technology Co., Ltd. We are overjoyed to have you as a cherished customer.
The A600 High-Performance Vector Control Inverter is an epitome of technological advancement, employing sophisticated flux vector control technology to ensure unmatched motor control, even in scenarios where motor parameters are not responsive. This state-of-the-art inverter guarantees comprehensive full-frequency, high-torque output, delivering rapid response times with outstanding load compatibility, precise speed management, and unwavering reliability. It is the ultimate choice for high-performance general-purpose inverters, impeccably catering to the meticulous demands across numerous sectors.
Crafted to harmoniously unite the general needs of customers with distinct industry demands, the A600 High-Performance Vector Control Inverter features a practical PID regulator, consistent pressure water supply, streamlined PLC, programmable input/output terminal control, remote synchronization, pulse frequency configurations, alongside an array of specialized inverter controls. These robust attributes provide a holistic solution for equipment manufacturing and automation engineering, considerably reducing system expenditures while bolstering system dependability.
This manual serves as an all-encompassing guide on equipment installation, operational parameter configurations, anomaly diagnostics, routine upkeep, and safe usage practices. To ensure the flawless installation and optimal functioning of the A600 High-Performance Vector Control Inverter, we earnestly advise a meticulous review of this manual prior to use. Incorporated within our product package for your ease, please retain this brochure for future reference.
If you encounter any challenges that cannot be resolved during the operation of this inverter, we urge you to connect with our distributors or directly contact our customer service center for prompt and efficient assistance.
At Jiangsu Robin Kang Automation Technology Co., Ltd., our commitment to technological innovation is paramount. Please be aware that the content within this manual is adaptable and may be altered without prior notice.

1.2 Inverter Model Description:
Voltage level Inverter model Rated Capacity(KVA) Rated output current(A) Fit motor(KW)
A600 A600-4T0300G/37P 39.5 60 30
A600-4T0370G/45P 49.4 75 37
A600-4T0450G/55P 62.5 90 45
A600-4T0550G/75P 75.7 110 55
A600-4T0750G/90P 98.7 150 75
A600-4T0900G/110P 115.8 176 90
A600-4T1100G/132P 138.2 210 110
A600-4T1320G/160P 171.1 260 132
A600-4T1600G/185P 204 310 160
A600-4T1850G/200P 236.9 360 185
A600-4T2000G/220P 253.4 385 200
A600-4T2200G/250P 276.4 420 220
A600-4T2500G/280P 312.6 475 250
A600-4T2800G/315P 352.1 535 280
A600-4T3150G/350P 391.6 595 315
A600-4T3500G/400P 43.4 660 350
A600-4T4000G/450P 500.0 730 400
A600-4T4500G/500P 565.0 840 450

1.4 Product Specifications and Specifications
enter Rated voltage, frequency Three-phase (4T series) 380V; 50 / 60HZ Three-phase (2T series) 220V: 50 / 60HZ
Allowable voltage range Three-phase (4T series) 320V ~ 460V  three-phase (2T series) 190V ~ 250V
Output Voltage 4T series; 0 ~ 380V 2T series; 0 ~ 220V
frequency Low frequency mode: 0 ~ 300HZ High frequency mode: 0 ~ 3000HZ
Overload capacity G-type machine: 110% long-term 150% 1 minute 180% 5 seconds
P-type machine: 105% long-term 120% 1 minute 150% 1 second
control method V / F control, advanced V / F control, V / F separation control, current vector control
Control features Frequency Set the resolution Analog input 0.1% of the maximum output frequency
Digital setting 0.01HZ
Frequency accuracy Analog input Within 0.2% of the maximum output frequency
Digital input Set the output frequency within 0.01%
V / F control V / F curve (voltage frequency characteristics) Reference frequency 5 ~ 600HZ arbitrarily set, multi-point V / F curve arbitrarily set, but also choose constant torque, low torque reduction 1, low torque reduction 2, square torque and other fixed curve
Torque boost Manual setting: 0.0 ~ 30.0% of rated output
Automatic boost: According to the output current and motor parameters automatically determine the lifting torque
Automatic current limiting and voltage limiting The motor stator current and voltage are automatically detected during acceleration, deceleration or steady operation, and are suppressed to within the allowable range according to the unique algorithm to minimize the possibility of system fault tripping
Control features No sense of vector control Voltage and frequency characteristics Output voltage to frequency ratio is automatically adjusted based on motor parameters and unique algorithms
Torque characteristics Starting torque:
150% of rated torque at 3.0Hz (VF control)
180% of rated torque at 0.5Hz (PG current vector control, flux vector control)
180% of rated torque at 0.05Hz (with PG current vector control)
Running speed steady-state accuracy: ≤ ± 0.2% rated synchronous speed
Speed fluctuation: ≤ ± 0.5% Rated synchronous speed
Torque response: ≤ 50ms PG vector control, PG vector control, flux vector control ≤ 20ms
 
Motor parameters self-test Without any restrictions, the parameters of the motor can be automatically detected in the static and dynamic motor, in order to obtain the best control effect
Current and voltage suppression Full current closed-loop control, completely avoid the current impact, with a perfect over-current over-voltage suppression
Undervoltage suppression during operation Especially for users with low grid voltage and frequent grid voltage fluctuation, the system can maintain the longest possible running time according to the unique algorithm and residual energy distribution strategy even if the voltage is below the allowable voltage range
Typical function Multi-speed and swing frequency operation 16 programmable multi-speed control, a variety of operating modes are optional. Swing frequency operation: preset frequency, adjustable center frequency, state memory and recovery after power off
PID control
RS485 communication
Built-in PID controller (presettable frequency) Standard configuration RS485 communication function, a variety of communication protocols optional, with linkage synchronization control function
Frequency setting Analog input DC voltage 0 ~ 10V, DC current 0 ~ 20mA (upper and lower limit optional)
Digital input Operation panel setting, RS485 interface setting, UP / DW terminal control, also can be combined with the analog input multiple settings
output signal Digital output 2 OC output and one fault relay output (TA, TB, TC), up to 16 meanings
Analog output 2 analog signal output, the output range of 0 ~ 20mA or 0 ~ 10V flexible set to achieve the set frequency, the output frequency and other physical output
Automatic voltage regulation According to the need to choose dynamic voltage regulator, static voltage regulator, unregulated three ways to get the most stable operating results
Increase, deceleration time setting 0.1S ~ 3600min can be set continuously, S-type, linear model optional
brake Energy consumption brake Energy consumption braking starting voltage, hysteresis voltage and energy consumption braking rate continuously adjustable
DC braking Stop DC braking start frequency: 0.00 ~ P0.16 upper limit frequency
Braking time: 0.0 ~ 100.0s; Braking current: 0.0% ~ 150.0% of rated current
Flux braking 0 ~ 100 0: invalid
Low noise operation Carrier frequency 1.0KHZ ~ 16.0KHZ continuously adjustable, to minimize motor noise
Speed tracking speed restart function It can realize the smooth restarting of the motor during operation and the restarting function of instantaneous stop
counter One internal counter to facilitate system integration
Run the function Upper and lower limit frequency setting, frequency jump operation, reverse run limit, slip frequency compensation, RS485 communication, frequency increment, decrement control, fault self-recovery operation

display Operation panel display Operating status Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc.
Alarm content Six recent fault records, the latest fault trip output frequency, set frequency, output current, output voltage, DC voltage, temperature and other six modules operating temperature records
Protective function Overcurrent, over voltage, undervoltage, module fault, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal tuning of motor parameters, internal memory failure, etc.
surroundings Ambient temperature -10 ºC ~ +40 ºC (ambient temperature 40 ºC ~ 50 ºC, please use derating)
Ambient humidity 5% ~ 95% RH, no condensation of water beads
surroundings Indoor (no direct sunlight, no corrosion, flammable gas, no oil mist, dust, etc.)
altitude Derate the use of more than 1,000 meters, every 1000 meters derated 10%
structure Degree of protection IP20
cooling method Air-cooled, with fan control
Installation method Wall-mounted, cabinet type

High-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz OutputHigh-Performance VFD for Plastic Machinery with 2000Hz Output

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier